AI power generation system, providing optimum performance, reliability, and versatility for stationery standby, prime power, and continuous duty applications. All generator sets are prototype tested, factory build, and production tested.
Open Type | ||
---|---|---|
Dimensions (LxWxH) | mm | 1860x900x1285 |
Dry Weight | kg | 1015 |
Sound Attenuated Type | ||
Dimensions (LxWxH) | mm | 2494x963x1542 |
Dry Weight | kg | 1335 |
Phase Rating, 50Hz, PF 0,8
Voltage | Standby Rating (ESP) | Prime Rating (PRP) | ||
---|---|---|---|---|
kVA | kW | kVA | kW | |
400/230 | 88 | 70.4 | 80 | 64 |
Standby Rating (ESP) : Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046.
Prime Rating (PRP) : Continuous running at variable load for unlimited periods with 10% overload for 1 hour in any 12 hour period. In accordance with ISO 8528, ISO 3046.
Manufacturer | Perkins | ||
---|---|---|---|
Model | 1104A-44TG2 | ||
Engine Power Output at rated rpm | kWm | 80.7 | |
HP | 108.2 | ||
No. of Cylinders and Build | 4 In Line | ||
Engine Speed | rpm | 1500 | |
Aspiration and Cooling | Turbocharged | ||
Total Displacement | L | 4.4 | |
Bore and Stroke | mm x mm | 105x127 | |
Compression Ratio | 17,25:1 | ||
Governor | Mechanical | ||
Fuel Consumption at full load | L/hr | 18.7 | |
Fuel Tank Capacity | Litre | 154 | |
Oil Capacity | Litre | 8 | |
Coolant Capacity | L | 13 | |
Radiator Cooling Air | m³ /min. | 89 | |
Air Intake - Engine | m³ /min. | 5.14 | |
Exhaust Gas Flow | m³ /min. | 13.3 |
Design | Brushless single bearing, revolving field/td> | |
---|---|---|
Stator | 2/3 pitch | |
Rotor | Single bearing, flexible disc | |
Insulation System | Class H | |
Standard Temperature Rise | 125 - 163°C Continuous | |
Exciter type | Self Excited | |
Phase Rotation | A (U), B (V), C (W) | |
Alternator Cooling | Direct drive centrifugal blower fan | |
AC Waveform Total Harmonic Distortion | No load <1.5% Non distorting balanced linear load < 5% | |
Telephone Influence Factor (TUF) | <50 per NEMA MG-1-22.43 | |
Telephone Harmonic Factor (THF) | <2% |
The experienced international network of Perkins suppliers, dealers and trained engine experts are available to deliver full time service support around the clock, 365 days a year. They have a selection of modern web based tools at their disposal to cover technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine over its life-cycle.